Freely programmable controller Exocompact

EXOcompact Vido is a 230 V AC freely programmable controller especially suitable for heating applications. It provides built-in communication via EXOline, Modbus or BACnet for integration into larger systems. It can be used either as a stand-alone unit or as part of a larger system.

 

Smoke control system, dampe rwith Modbus communication

Damper unit with Modbus communication to be connected to a Modbus master controller. Can be connected to the Regin:GO app through Bluetooth® for easier commissioning. You can connect a damper actuator (Fire damper, smoke control damper , 0-10V (VAV) or no damper actuator), temperature sensor(s) and/or smoke detector.

Electric heating controller with PI-control, 230…400 V AC, DIN-rail mounting

The PULSER/D is an electric heating controller with PI control, suitable for 1 or 2-phase systems operating at 230 to 400 V AC. It features DIN-rail mounting, an IP20 protection class, and a setpoint range of 0 to 30°C. The controller has a 60-second pulse period, supports NTC Regin standard sensor input, and includes a red LED indicator for power status. It is designed for environments with ambient temperatures from 0 to 40°C and humidity up to 90% RH, non-condensing.

I/O Module with 7 or 10 input/output

I/O module for expansion of Regin’s freely programmable EXOclever, EXOflex, EXOcompact and EXOdos controllers.

Control units for smoke detectors

The ABV24-S-300/D is a control unit for smoke detectors with a service alarm, operating on a 24 V AC/DC power supply. It features DIN-rail mounting, IP20 protection, and dimensions of 53x85x74 mm. The unit has a normal current consumption of 30 mA and 70 mA during an alarm, with outputs for smoke and service alarms.

Exigo Vido 19 I/O’s, display, 1 RS485, 1 TCP/IP

Exigo Vido are controllers for heating and boiler control that make every step from installation to operation and maintenance easier than ever. Simply connect the controller, enter any settings as desired and start up. It can be used either stand-alone or integrated into a network. It has built-in support for many different languages and is designed for mounting on a DIN-rail, in a cabinet door or directly on a wall.

Exigo Vido 19 I/O’s, display, 1 TCP/IP

Exigo Vido are controllers for heating and boiler control that make every step from installation to operation and maintenance easier than ever. Simply connect the controller, enter any settings as desired and start up. It can be used either stand-alone or integrated into a network. It has built-in support for many different languages and is designed for mounting on a DIN-rail, in a cabinet door or directly on a wall.

Exigo Vido 20 I/O’s, display, 1 RS485 1 M-Bus, 1 TCP/IP

Exigo Vido are controllers for heating and boiler control that make every step from installation to operation and maintenance easier than ever. Simply connect the controller, enter any settings as desired and start up. It can be used either stand-alone or integrated into a network. It has built-in support for many different languages and is designed for mounting on a DIN-rail, in a cabinet door or directly on a wall.

Exigo Ardo 15 I/O’s, display, 1 RS485, 1 TCP/IP

Exigo Ardo are controllers for heating and boiler control that make every step from installation to operation and maintenance easier than ever. Simply connect the controller, enter any settings as desired and start up. It can be used either stand-alone or integrated into a network. It has built-in support for many different languages and is designed for mounting on a DIN-rail or in a cabinet door.

Exigo Ardo 28 I/O’s, display, 1 RS485, 1 TCP/IP

Exigo Ardo are controllers for heating and boiler control that make every step from installation to operation and maintenance easier than ever. Simply connect the controller, enter any settings as desired and start up. It can be used either stand-alone or integrated into a network. It has built-in support for many different languages and is designed for mounting on a DIN-rail or in a cabinet door.

Exigo Ardo 15 I/O’s, 1 RS485, 1 TCP/IP

Exigo Ardo are controllers for heating and boiler control that make every step from installation to operation and maintenance easier than ever. Simply connect the controller, enter any settings as desired and start up. It can be used either stand-alone or integrated into a network. It has built-in support for many different languages and is designed for mounting on a DIN-rail or in a cabinet door.

Exigo Ardo 28 I/O’s, display, 1 RS485, 1 M-Bus, 1 TCP/IP

Exigo Ardo are controllers for heating and boiler control that make every step from installation to operation and maintenance easier than ever. Simply connect the controller, enter any settings as desired and start up. It can be used either stand-alone or integrated into a network. It has built-in support for many different languages and is designed for mounting on a DIN-rail or in a cabinet door.

Exigo Ardo 28 I/O’s, 1 RS485, 1 M-Bus, 1 TCP/IP

Exigo Ardo are controllers for heating and boiler control that make every step from installation to operation and maintenance easier than ever. Simply connect the controller, enter any settings as desired and start up. It can be used either stand-alone or integrated into a network. It has built-in support for many different languages and is designed for mounting on a DIN-rail or in a cabinet door.

Step controller, 0-10V to 2 on/off (sequence or binary), 24V, DIN-rail

Step controller with 2 relays (closing)

Step controller, 0-10V to 1 on/off, 24V, DIN-rail mounting

Step controller with 1 relay (change-over)

Room controller, 0…10V or On/Off, hidden, com, CO2 single beam

Regio Midi are controllers with a built-in temperature sensor and an RS485 communication port. Controllers in different rooms and zones can be connected to a bus line enabling communication with a central SCADA system via RS485 (EXOline, BACnet (only display versions) or Modbus).

Room controller, 0…10V or On/Off, hidden, com, CO2 single beam

Regio Midi are controllers with a built-in temperature sensor and an RS485 communication port. Controllers in different rooms and zones can be connected to a bus line enabling communication with a central SCADA system via RS485 (EXOline, BACnet (only display versions) or Modbus).

Room Controller, 0…10V or On/off, display, com, CO2 single beam

Regio Midi are controllers with a built-in temperature sensor and an RS485 communication port. Controllers in different rooms and zones can be connected to a bus line enabling communication with a central SCADA system via RS485 (EXOline, BACnet (only display versions) or Modbus).

Regio zone controller, 0-10V or on/off, occupancy, communication, room

Regio Midi are controllers with a built-in temperature sensor and an RS485 communication port. Controllers in different rooms and zones can be connected to a bus line enabling communication with a central SCADA system via RS485 (EXOline, BACnet (only display versions) or Modbus).

 

Regio zone controller, 0-10V or on/off, hidden setpoint, comm, room

Regio Midi are controllers with a built-in temperature sensor and an RS485 communication port. Controllers in different rooms and zones can be connected to a bus line enabling communication with a central SCADA system via RS485 (EXOline, BACnet (only display versions) or Modbus).

Regio zone controller, 0-10V or on/off, hidden setpoint, comm, room

Regio Midi are controllers with a built-in temperature sensor and an RS485 communication port. Controllers in different rooms and zones can be connected to a bus line enabling communication with a central SCADA system via RS485 (EXOline, BACnet (only display versions) or Modbus).

Regio zone controller, 0-10V or on/off, occup, displ, CO2, comm, room

Regio Midi are controllers with a built-in temperature sensor and an RS485 communication port. Controllers in different rooms and zones can be connected to a bus line enabling communication with a central SCADA system via RS485 (EXOline, BACnet (only display versions) or Modbus).

Regio zone controller, 0-10V or on/off, occup, fan ctrl, comm, room

Regio Midi are controllers with a built-in temperature sensor and an RS485 communication port. Controllers in different rooms and zones can be connected to a bus line enabling communication with a central SCADA system via RS485 (EXOline, BACnet (only display versions) or Modbus).

Regio zone controller, 0-10V or on/off, setpoint, communication, room

Regio Midi are controllers with a built-in temperature sensor and an RS485 communication port. Controllers in different rooms and zones can be connected to a bus line enabling communication with a central SCADA system via RS485 (EXOline, BACnet (only display versions) or Modbus).

Regio Ardo, 20 I/O, 2 x RS485, Ethernet, terminal protection

Regio Ardo is a configurable 24 V zone controller. One controller is able to control two different zones.
It is quick and easy to commission. The I/O configuration and application setup for a VAV controlled room are predefined and the room units ED-RU are easily connected. The controller is compatible with other Regin products and can easily be integrated into larger systems.
The controller can be used in systems with communication, e.g. EXOline, Modbus or BACnet (over RS485 or TCP/IP). It is installed in a ceiling void, on a junction box plate or on a DIN-rail.

Optigo, controller, 5 I/Os, 24V, display, DIN-rail mounting

Controller for control of temperature, CO2 and pressure.

 

 

 

Optigo, controller, 10 I/Os, 24V, display, DIN-rail mounting

Controller for temperature.

 

 

 

Optigo, controller, 10 I/Os, 230V, display, DIN-rail mounting

Controller for temperature.

 

 

 

Corrigo 28 I/Os, display, 2 RS485, 1 TCP/IP, web server

Corrigo comes preloaded with applications for control of ventilation.

Corrigo running a ventilation application is intended for control of air handling units with temperature control, 1- or 2-speed operation or, alternatively, pressure or air flow control of supply air fan and extract air fan, humidity control as well as other common functions in ventilation.